PRODUCTS
ATTEN ST-8800D Hot Air Station (UK Plug)
MODEL: ST-8800D
(per piece)
♦ Specifications: |
Model |
ST-8800D |
Power consumption |
800W (MAX) |
Input voltage |
AC230V±10% 50Hz (110V±10% 60Hz Optional) |
Temperature range |
100℃~500℃/212℉~932℉ |
Setting range of setting volume |
10-100% |
Air flow |
30~120L/min |
Standby heater cooling function |
Support |
Beeping function |
Available |
Timing function |
Available |
Standby Function |
Available |
Shortcut temperature |
3 sets |
Temperature calibration |
±50°C/±90°F |
Temperature adjustment |
1 digit |
Air flow adjustment |
1 digit |
Working conditions |
Temperature 0-40°C, relative humidity <80% |
Storage conditions |
Temperature -20-80°C, relative humidity <80% |
Auto-sleep function |
Available |
Dimensions |
16.7*14.2*14.8cm |
Net weight |
1.6kg |
♦ Easy Temperature/Air Flow Setting
1. Adjust the air flow value by AIR knob, "+" / "-" to increase/reduce the air volume.
2. Adjust the temperature value by pressing “▲” or “▼”, long press can be quickly adjusted.
♦ Saving and Call Shortcut Temperature
Press button “1”/ “2”/ “3” to call or save preset temperature and air flow value.
♦ Timing function
Under the HT menu, press “▲” and “▼” keys to adjust the timing function working time. The setting time is 10 - 900 seconds.
♦ Standby Function
The hot air gun stand-by function can adjust in menu, “---” means standby. The hot air gun blows at the maximum air volume when the handle is placed on the holder, then enter stand-by status when the temperature drops under 100 ° C or stop heating after 15 seconds. The machine will return to work when picking up the handle.
♦ Auto-sleep function
The hot air station will automatic enter the sleep status and display OFF after 30 minutes of no activity, and it won't re-work when the handle dropped or picked up until press any button to awaken.
♦ Temperature Lock Function
Under Loc Menu, it can turn on/off temperature lock function by pressing “▲” or “▼” key.
♦ ℃/℉ available
In menu C-F mode, it can switch temperature unit ℃/℉ by pressing “▲” or “▼” key.
♦ Temperature Calibration
Under menu CAL mode, press “▲”or“▼” key to adjust the value. Calibration range is -50℃~ 50℃(-90℉~90℉). Calibration value will be negative as actual-measured temperature is lower than setting temperature; Calibration value will be positive as actual-measured temperature is higher than setting temperature.
♦ Beeping function
Under menu BL mode, it can turn on/ off the beeping function by pressing “▲” or “▼”key.
♦ Password Setting Function
In PSD menu, press “▲” or “▼” to adjust password setting value, which can be set from 01 to 999. “00” means password function is off. Default no password for the first time entrance. (Note: Directly input 906 password to enter menu in case of forgot the password.)
♦ Fault alarm function
S-E |
Sensor fault. |
H-E |
Heating element fault. |